Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
11.2.1, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2
Fixed In:
13.0.0, 12.1.2 HF1
Opened: Nov 18, 2016 Severity: 3-Major
When you run the command tmsh show sys perf, you get an error: 011b030d:3: Graph 'dnsx' not found This can also occur with other tmsh commands related to performance statistics, like show sys perf dnssec and show sys perf dnsexpress.
Certain tmsh sys perf commands fail to work and give an error.
It is not known what exactly triggers this, it is caused by a timing issue that occurs during system initialization of multi-blade chassis.
Restart statsd on all blades once the chassis is up. e.g. "bigstart restart statsd" on each blade.
statsd has been updated to reparse the statsd config file before rebuild it's config so that it doesn't lose the unsupported tables in it's list.