Last Modified: Nov 07, 2022
Affected Product:
See more info
BIG-IP GTM
Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.10, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2
Fixed In:
13.0.0, 12.1.2 HF1, 11.6.3, 11.5.7
Opened: Nov 19, 2016
Severity: 3-Major
Related Article:
K53675033
Some monitored resources are marked as "Unknown" when the actual status is "offline".
The status of the monitored resource is incorrect. This does not materially affect the operation of the system since resources marked "Unknown" will not be used.
This can rarely occur when the monitor timeout period elapses when either no response has been received, or a response has been received indicating that the resource is "down" and the monitor is configured to ignore down responses. It is more likely to occur when many monitor timeout periods elapse at the same time, and the monitor timeout value is evenly divisible by the monitor's monitor interval.
Disable the affected resources, and then enable them again.
The resource status is now correct under all monitor timeout conditions.