Bug ID 633472: Deployment fails with "Could not determine which real kinds mapped to intermediate kind ADC_MONITOR_TCP_HALF_OPEN"

Last Modified: May 29, 2024

Affected Product(s):
BIG-IQ ADC(all modules)

Known Affected Versions:
5.1.0

Opened: Dec 14, 2016

Severity: 3-Major

Symptoms

When deploying a change to one or more managed devices, deployment fails and restjavad shows an error similar to: AdcClusterDistributeTaskWorker] Error parsing difference summary: java.lang.IllegalArgumentException: Could not determine which real kinds mapped to intermediate kind ADC_MONITOR_TCP_HALF_OPEN

Impact

Deployment fails.

Conditions

This issue applies when: 1) The deployment contains a change where a TCP monitor is involved (i.e. creating a new pool with such a monitor attached); 2) The deployment target is a BIG-IP cluster; 3) A TCP monitor exists with the same name in two or more managed devices, but it has different properties in at least one of the devices.

Workaround

Avoid having TCP monitors with same name but different properties across managed devices.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips