Bug ID 642058: CBL-0138-01 Active Copper does not work on i2000/i4000/HRC-i2800 Series appliances

Last Modified: Nov 07, 2022

Bug Tracker

Affected Product:  See more info
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 13.0.0

Fixed In:
13.0.0 HF1, 12.1.2 HF1

Opened: Jan 28, 2017
Severity: 1-Blocking
Related Article:
K20528400

Symptoms

CBL-0138-01 will not come up or show link on i2000/i4000/HRC-i2800 series appliances. The following message will appear on the LCD: 0 01/30/17 09:02:59 error 0x1660016 Interface 5.0 detected a non 10GbE optic The following message will appear in /var/log/ltm: err pfmand[7630]: 01660016:3: Interface 5.0 detected a non 10GbE optic The interface will report in tmsh as down: tmsh show net interface 5.0 -------------------------------------------------------- Net::Interface Name Status Bits Bits Pkts Pkts Drops Errs Media In Out In Out -------------------------------------------------------- 5.0 down 0 0 0 0 0 0 none

Impact

The CBL-0138-01 will not work.

Conditions

i2000/i4000/HRC-i2800 series appliances and CBL-0138-01.

Workaround

None.

Fix Information

CBL-0138-01 Active Copper now works correctly on i2000/i4000/HRC-i2800 Series appliances.

Behavior Change