Bug ID 649336: AVR doesn't display units for "Avg Read Latency" measurement

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP AFM, ASM, AVR(all modules)

Known Affected Versions:
11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Fixed In:
13.1.0

Opened: Mar 07, 2017

Severity: 4-Minor

Symptoms

AVR doesn't display units for 'Avg Read Latency'.

Impact

No units are displayed.

Conditions

AVR, ASM, DoS, or AFM are provisioned.

Workaround

1. edit the following file: /etc/avr/monpd/monp_disk_info_measures.cfg 2. add the following line at line 63: "units=microsecond" 3. restart monpd.

Fix Information

Added units (microsecond) to AVR report.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips