Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1
Fixed In:
14.0.0
Opened: Mar 08, 2017 Severity: 3-Major
Unsupported power supplies are misleadingly reported as "not-present" when inserted into the system even when power is actively supplied to them. For example, if a system had a valid AC PSU in slot #1 but an unsupported PSU in slot #2: #tmsh show sys hard|grep -A 4 Power Chassis Power Supply Status Index Status Current 1 up AC 2 not-present NA
Misleading information is given for the power supply as 'not-present' rather than 'unidentified'. System is in an unsupported electrical state and without power redundancy.
-- A power supply unit that fits mechanically into the system but is not supported electrically is inserted and powered on. -- Inserted in 2xxx/4xxx/5xxx/7xxx/10xxx series platforms.
There is no workaround at this time.
When an unsupported power supply is inserted into the system, it is now reported as 'unidentified'. In addition, a critical alarm will be raised to the LCD and written to the LTM log. For example, if a system had a valid AC PSU in slot #1 but an unsupported PSU in slot #2: # tmsh show sys hard|grep -A 4 Power Chassis Power Supply Status Index Status Current 1 up AC 2 unidentified NA The system reports the following critical alarm: critical 0x12a0059 Chassis power module 2 is unidentified.