Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP All
Known Affected Versions:
13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1
Opened: Mar 16, 2017 Severity: 3-Major
When port is configured in passive mode, to handle untagged frames, the system requires a VLAN to be configured on the system.
Must define a VLAN to process untagged data received on port operating in Passive mode. Might impact system performance.
-- When port is operating in passive mode. -- Handling untagged frames.
Use the following procedure: 1. Create a VLAN. 2. Assign passive mode port as an untagged member of the VLAN.
None