Bug ID 653930: Monitor with description containing backslash may fail to load.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP DNS, GTM, LTM(all modules)

Known Affected Versions:
11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Fixed In:
13.1.0, 12.1.4

Opened: Mar 28, 2017

Severity: 3-Major

Related Article: K69713140

Symptoms

When a monitor description contains a \ (backslash) character, the system adds another backslash for every save-load operation. After enough saves/loads, the description eventually hits the maximum length, causing an error message: '01020057:3: The string with more than 65535 characters cannot be stored in a message' upon loading the config.

Impact

Configuration changes without human intervention. Potential load failure.

Conditions

Monitor with description containing backslash.

Workaround

Don't use backslashes in monitor descriptions.

Fix Information