Bug ID 658298: SMB monitor marks node down when file not specified

Last Modified: May 14, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5

Fixed In:
13.1.0, 12.1.3.6

Opened: Apr 13, 2017
Severity: 4-Minor

Symptoms

The smb monitor may always mark the node down when the file is not specified in the monitor config.

Impact

Service impact due to node being marked down.

Conditions

Pool member monitored with smb monitor.

Workaround

Configure monitor to fetch file (authenticated).

Fix Information

None

Behavior Change