Bug ID 659281: "Severe critical" message after failed upgrade persists even after subsequent successful config load

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP Install/Upgrade(all modules)

Known Affected Versions:
12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6

Fixed In:
13.1.0

Opened: Apr 19, 2017

Severity: 3-Major

Symptoms

A critical message persists in the GUI after a failed upgrade: ---------------------------------------------------------------------- ASM Critical Warning An upgrade process was interrupted. It is very likely that ASM will start with a severe inconsistent interal state and critical errors ----------------------------------------------------------------------

Impact

A critical message persists in GUI, even after a successful subsequent configuration load.

Conditions

ASM upgrade has failed.

Workaround

None

Fix Information

Subsequent successful configuration load now clears failed upgrade message.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips