Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1
Fixed In:
13.1.0
Opened: Apr 24, 2017 Severity: 3-Major Related Article:
K36005385
When the monitor is configured with a timeout large enough that the timeout plus interval is greater than 86400 seconds, the service may be incorrectly marked down.
Periodically service taken offline which may result in persistence issues or impact service availability.
Monitor configured with timeout plus interval larger than 86400.
Reduce the monitor's timeout to less than (86400 - interval).
None