Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3
Fixed In:
13.1.0, 13.0.1, 12.1.3.2
Opened: May 10, 2017 Severity: 3-Major
If OCSP is configured with certain responders, a valid response may be rejected with the following error: OCSP response: got EOF
Valid OCSP responses may be rejected.
This is entirely dependent on the behavior of the server. If a responder sends null or blank data (but does not close the connection) OCSP simply ends the response.
None.
These responses are now accepted.