Last Modified: Aug 19, 2026
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.6.0, 11.6.0 hf1, 11.6.0 hf2, 11.6.0 hf3, 11.6.0 hf4, 11.6.0 hf5, 11.6.0 hf6, 11.6.0 hf7, 11.6.0 hf8, 11.6.1, 11.6.1 hf1, 11.6.1 hf2, 11.6.2, 11.6.2 hf1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 hf1, 12.0.0 hf2, 12.0.0 hf3, 12.0.0 hf4, 12.1.0, 12.1.0 hf1, 12.1.0 hf2, 12.1.1, 12.1.1 hf1, 12.1.1 hf2, 12.1.2, 12.1.2 hf1, 12.1.2 hf2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 hf1, 13.0.0 hf2, 13.0.0 hf3, 13.0.1
Fixed In:
14.0.0, 13.1.0
Opened: May 30, 2017 Severity: 3-Major Related Article:
K21090061
Failure occurs when attempting to configure or load OSPF configurations in imish using an interface-level command similar to the following: ip ospf <IP> message-digest-key <key index> md5 <password>.
The command causes an error and cannot be used or loaded. This may cause OSPFv2 adjacencies to fail.
This occurs when using the following command: ip ospf <IP> message-digest-key.
If possible, use the non-IP version of the interface-level command, similar to the following: ip ospf message-digest-key <key index> md5 <password>.
The BIG-IP system now correctly loads the ZebOS 'ip ospf <IP> message-digest-key' interface-level command.