Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1
Fixed In:
12.1.3.3
Opened: Jul 17, 2017 Severity: 3-Major Related Article:
K62223225
When creating more than one node with FQDN configured with monitors, monitors are not displayed in the GUI properly.
The previously created FQDN node does not display monitors in the GUI. However, the subsequently created FQDN node does display the correct monitors.
Create more than one node with FQDN configured.
Use tmsh to view monitors for Nodes with FQDN configured.
Node page now displays the correct monitors for nodes configured with FQDN.