Bug ID 676203: Inter-blade mpi connection fails, does not recover, and eventually all memory consumed.

Last Modified: Oct 16, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7

Fixed In:
14.0.0, 13.1.0.8, 12.1.3.2

Opened: Jul 29, 2017

Severity: 2-Critical

Symptoms

TMM memory usage suddenly increases rapidly.

Impact

Inter-blade mpi requests do not complete and the system eventually exhausts memory.

Conditions

The inter-blade mpi connection fails and does not recover.

Workaround

None.

Fix Information

Inter-blade mpi connection now continues as expected, without memory issues.

Behavior Change

Guides & references