Bug ID 678716: GUI Unexpected changes to sFlow values when configuring using the GUI

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1

Fixed In:
14.0.0

Opened: Aug 16, 2017

Severity: 3-Major

Symptoms

When configuring the sFlow values in the GUI, the value can unexpectedly change if you choose Default in the drop down.

Impact

The system might update the Global Settings value, which might cause confusion.

Conditions

-- Configuring an HTTP Profile, Interface, or VLAN with sFlow values. -- Select 'Default' from the drop down.

Workaround

Use tmsh to independently update the sFlow values.

Fix Information

The GUI now manages the sFlow values independently.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips