Bug ID 682369: Inserting an un-powered PSU and then removing the un-powered PSU puts the BMC into an incorrect PSU status state.

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IP AOM(all modules)

Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1

Fixed In:
14.1.0

Opened: Sep 08, 2017

Severity: 3-Major

Symptoms

Inserting an un-powered PSU and then removing the un-powered PSU puts the BMC into an incorrect PSU status state. Once in this PSU incorrect status state, the BMC reports an input-lost alert on every subsequent host reboot until the PSU is re-installed, or the BMC is reset.

Impact

On every subsequent host reboot the system reports an input-lost alert for the not-present PSU in the ltm log, the LCD posts a warning, and the system alarm LED turns yellow.

Conditions

-- System is powered by a single PSU. -- A second un-powered PSU is inserted and then removed.

Workaround

Re-install the second PSU, reboot the AOM via the console AOM menu, or power cycle the platform.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips