Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP All, Install/Upgrade
Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1
Fixed In:
14.0.0, 13.1.0.2
Opened: Dec 11, 2017 Severity: 2-Critical
Sys load fails with following errors, .... Loading schema version: 14.0.0 0107153e:3: Application id out of the valid range of [8192-16384). Unexpected Error: Loading configuration process failed.
System will fail to come to Active state after upgrade.
When an CEC IM is applied to 12.1.2 and then when we upgrade to 13.x or 14.x, sys load will fail.
It can be fixed by manually deleting /var/libdata/dpi/conf/classification_update.conf
None