Bug ID 699898: Wrong policy version time in policy created after synchronization between active and stand by machines.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1

Fixed In:
14.0.0

Opened: Dec 25, 2017

Severity: 3-Major

Symptoms

After synchronization, the policy version time in the policy created on the standby BIG-IP system is different from the policy version time on the original policy on the active BIG-IP system.

Impact

Policy version timestamp on standby system is not synchronized properly.

Conditions

Synchronizing the new policies on the active system with new policies on the standby system.

Workaround

Run full synchronization again from active system to the group.

Fix Information

The policy version time in the policy created on the standby BIG-IP system now matches the policy version time on the original policy on the active BIG-IP system.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips