Last Modified: Jul 13, 2024
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 14.0.0, 14.0.0.1, 14.0.0.2
Fixed In:
14.1.0, 14.0.0.3, 13.1.1.2, 12.1.3.6
Opened: Feb 26, 2018 Severity: 3-Major
-- 'tmctl -d blade tmm/umem_usage_stat | grep xdata' may show increased memory usage. -- 'tmsh show sys connect' shows idle flows.
- Some flows are mirrored incorrectly. - Stalled flows may occupy a lot of memory.
- OneConnect profile is configured. - High availability (HA) mirroring is enabled.
Disable OneConnect.
Stalled mirrored flows no longer appear when OneConnect is used.