Bug ID 718201: No alert for failed RAID disk

Last Modified: Jul 13, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6

Fixed In:
14.1.0

Opened: May 03, 2018

Severity: 3-Major

Symptoms

If a BIG-IP system boots with a failed drive in a RAID array, no alert will be logged.

Impact

There is no warning that the system is not operating in a mirrored RAID state.

Conditions

-- BIG-IP system with dual SSDs. -- One of the drives has previously failed. -- The system is booted/rebooted.

Workaround

Run 'tmsh show sys raid disk all-properties' to show the status of the RAID array

Fix Information

None