Bug ID 721338: Error creating application service from imported iApp Template

Last Modified: Sep 14, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 14.1.5.1, 14.1.5.2, 14.1.5.3, 14.1.5.4, 14.1.5.6, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4

Opened: May 22, 2018

Severity: 3-Major

Symptoms

When creating app service from an imported iApp template, the system might generate error messages similar to following examples: -- Error parsing template:can't eval proc: "script::run" script does not exist while executing "tmsh::run_proc f5.iapp.1.5.3.cli:tmsh::run_proc f5.iapp.1.5.6.cli:iapp_safe_display ::choices" (procedure "script::run" line 3) invoked from within "script::run" line:1. -- notice scriptd[30977]: 014f0005:5: AUDIT - user=testuser1 action="run stand-alone script: Script" status="can't eval proc: "script::run" script does not exist.

Impact

Cannot deploy application service from imported iApp.

Conditions

Create a new virtual server using an imported iApp template.

Workaround

Although there is no workaround that prevents the issue, you can recover by forcing the mcpd process to reload the BIG-IP configuration. To do so, follow the steps in K13030: Forcing the mcpd process to reload the BIG-IP configuration :: https://support.f5.com/csp/article/K13030.

Fix Information

None