Bug ID 748030: Modifying datagroup type at runtime is not supported

Last Modified: Oct 17, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1

Opened: Oct 26, 2018

Severity: 4-Minor

Symptoms

After a hand-edit of BIG-IP configuration to modify a datagroup's type, "tmsh load sys config" appears to succeed without error. However, the datagroup type change does not take effect.

Impact

Datagroup and the rules which reference it do not behave as expected.

Conditions

Edit datagroup type by hand.

Workaround

If feasible, create a new datagroup with the desired type.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips