Bug ID 750666: Impossible to create Bot Signature/Bot Category Signature in user partition different from 'Common'

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
14.1.0, 14.1.0.1

Fixed In:
15.0.0, 14.1.0.2

Opened: Nov 21, 2018

Severity: 3-Major

Symptoms

For any partition other than 'Common'(i.e., a user-defined partition), cannot create a new Bot Signature or Bot Category Signature via GUI, because the form fields and buttons are disabled (grayed out).

Impact

No creation of Bot Signature/Bot Category Signature can be completed through GUI in a user-defined partition.

Conditions

-- Creating Bot Signature/Bot Category Signature. -- The partition is set to a user-defined partition.

Workaround

Create Bot Signature/Bot Category Signature in TMSH.

Fix Information

Can now create Bot Signature/Bot Category Signature in user partition different from 'Common'.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips