Bug ID 752530: TCP Analytics: Fast L4 TCP Analytics reports incorrect goodput.

Last Modified: Jul 03, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.4, 14.1.0.5, 14.1.0.6

Fixed In:
15.0.0

Opened: Dec 10, 2018
Severity: 3-Major

Symptoms

Fast L4 TCP Analytics reports incorrect goodput when server sequence number and the TMM generated sequence number are different.

Impact

The GUI page Statistics :: Analytics :: TCP :: Goodput page displays incorrect goodput values.

Conditions

This occurs when either of the following conditions are met: -- tcp-generate-isn is set in the Fast L4 profile. -- SYN cookie is active.

Workaround

None.

Fix Information

Fast L4 TCP Analytics now shows correct goodput values when server sequence number and the TMM generated sequence number are different.

Behavior Change