Bug ID 757423: Statistics collected from devices in sync/failover clusters

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IQ AppIQ(all modules)

Known Affected Versions:
6.1.0

Fixed In:
7.0.0

Opened: Feb 01, 2019

Severity: 2-Critical

Symptoms

When managed BIG-IP devices are configured in a DSC group, BIG-IQ does not collect statistics from all managed devices.

Impact

Statistics are not collected for all the managed BIG-IP devices. In addition, the managed BIG-IP devices get into an out-of-sync config state that is reported as a state that needs attention. -- A common symptom is the 'Stats Last Collection Date' shows up as Dec 31, 1969 or Jan 01, 1970, depending the timezone configuration of the device. -- The 'Stats Last Collection Date' shows up as '--'. -- The BIG-IP systems incorrectly identify themselves to BIG-IQ. -- The BIG-IP systems do not report at all, even if they are configured to report. Note: This bug is tightly related to BIG-IP Bug ID 753485: AVR global settings are being overridden by HA peers :: https://cdn.f5.com/product/bugtracker/ID753485.html.

Conditions

Statistics collection enabled for managed BIG-IP devices in a DSC group.

Workaround

None.

Fix Information

This issue is fixed in BIG-IQ version 7.0, for managed BIG-IP devices running the following versions: -- 13.1.2.0, or a later 13.1.x version. -- 14.1.0.7, or a later 14.1.x version. -- 15.0.0.1, or a later 15.0.x version.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips