Bug ID 760439: After installing a UCS that was taken in forced-offline state, the unit may release forced-offline status

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 15.0.0, 15.0.1

Fixed In:
15.1.0, 15.0.1.1, 14.1.2.3, 13.1.3.4, 12.1.5.3

Opened: Mar 05, 2019

Severity: 3-Major

Symptoms

After installing a UCS that was taken in forced-offline state, the unit may release forced-offline status (e.g., transitions to standby or active).

Impact

Unit may become active/standby before intended (e.g., during maintenance).

Conditions

Installing UCS that was taken in forced-offline state on clean installed unit.

Workaround

After installing the UCS, ensure that the unit is in forced-offline state as intended. If not in forced-offline state, force the unit offline before proceeding.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips