Bug ID 814145: GUI SIP monitor fails to create/update when status code is empty

Last Modified: Dec 13, 2023

Affected Product(s):
BIG-IP GTM(all modules)

Known Affected Versions:
15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 15.1.6.1, 15.1.7, 15.1.8, 15.1.8.1, 15.1.8.2, 15.1.9, 15.1.9.1, 15.1.10, 15.1.10.2, 15.1.10.3

Fixed In:
16.0.0

Opened: Aug 12, 2019

Severity: 3-Major

Symptoms

GUI reports 'General database error.', and SIP monitor is not created/updated.

Impact

GUI reports an error. Unable to create/update SIP monitor using GUI.

Conditions

-- Select a status code list value for additional status codes option. -- Do not add any status codes or remove all existing status codes.

Workaround

Change the value of Additional status code options to 'None' if you do not want to add any status codes.

Fix Information

The system now presents an Alert Message when trying to create or update a SIP monitor without a Status Code when the Status Code List is selected.

Behavior Change

Guides & references