12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.4, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.1.0

Opened: Sep 13, 2019
Severity: 3-Major

Symptoms

Many SNMPv3 clients pay attention to the engineBoots value as part of server authentication. When the BIG-IP system is upgraded, the engineBoots value is not retained, so it restarts at 1.

Impact

The engineBoots value is reset to 1. This may look like an error condition for the SNMPv3 client.

Conditions

Upgrading a BIG-IP system whose engineBoots value is greater than 1.

Workaround

1. Run the following command (where n = the value at which you want to start the engineBoots): tmsh modify sys snmp include 'engineBoots n' 2. Restart SNMPD.

Fix Information

None