Bug ID 846425: APM configsnapshot are not created when blade transitions from secondary to primary

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6

Opened: Nov 05, 2019

Severity: 3-Major

Symptoms

In a chassis, when a secondary blade transitions to the primary blade it is responsible for keeping APM configuration snapshots current. However, prior to 13.1.0, APM configuration snapshots are not maintained.

Impact

Cannot access any APM functionality

Conditions

-- APM configured in a multi-bladed chassis. -- Secondary blade transitions to primary blade.

Workaround

Restart the apd process using the following command on the new primary blade: # bigstart restart apmd

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips