Bug ID 885769: The ASM logging Operation_id field has incorrect byte at the end

Last Modified: May 29, 2024

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2

Fixed In:
16.1.0

Opened: Feb 27, 2020

Severity: 3-Major

Symptoms

The operation ID field has one incorrect byte at the end of the string.

Impact

In the remote log, the operation ID reports the incorrect byte, which might lead to confusion.

Conditions

This can occur if the operation ID is 255 bytes long.

Workaround

None.

Fix Information

Eliminated the extra byte at the end of the operation ID.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips