Bug ID 886649: Connections stall when dynamic BWC policy is changed via GUI and TMSH

Last Modified: Feb 07, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 14.1.4.6, 14.1.5, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 15.1.5.1, 15.1.6, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2

Fixed In:
17.1.0, 17.0.0.1, 16.1.3, 15.1.6.1, 14.1.5.1

Opened: Mar 02, 2020

Severity: 3-Major

Symptoms

Connections stall when dynamic BWC policy is changed via GUI and TMSH.

Impact

Connection does not transfer data.

Conditions

Issue is seen when you have a dynamic bandwidth control policy configured, and you make a change to the policy via the GUI and TMSH.

Workaround

Restart TMM. Delete the relevant configuration, create a new configuration, and apply it.

Fix Information

None