Bug ID 898341: BIG-IP may stop sending statistics following a DCD reboot

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IQ AppIQ(all modules)

Known Affected Versions:
7.0.0.1, 7.0.0.2, 7.1.0, 7.1.0.1, 7.1.0.2, 7.1.0.3, 7.1.6, 7.1.6.1, 7.1.7, 7.1.7.1, 7.1.7.2, 7.1.8, 7.1.8.1, 7.1.8.2, 7.1.8.3, 7.1.8.4, 7.1.8.5, 7.1.9, 7.1.9.7, 7.1.9.8, 7.1.9.9

Opened: Apr 13, 2020

Severity: 3-Major

Symptoms

After rebooting a data collection device, the monitored BIG-IPs might not send statistics to the rebooted DCD.

Impact

Affected BIG-IPs aren't sending statistics

Conditions

BIG-IQ CM and DCDs are rebooted.

Workaround

Workaround: Re-enable stats (from BIG-IQ) to the disconnected BIG-IP.

Fix Information

None

Behavior Change

Guides & references