Last Modified: Jun 19, 2025
Affected Product(s):
BIG-IQ ADC
Known Affected Versions:
7.1.0, 7.1.0.1, 7.1.0.2, 7.1.0.3, 7.1.6, 7.1.6.1, 7.1.7, 7.1.7.1, 7.1.7.2, 7.1.8, 7.1.8.1, 7.1.8.2, 7.1.8.3, 7.1.8.4, 7.1.8.5, 7.1.9, 7.1.9.7, 7.1.9.8, 7.1.9.9
Opened: Apr 20, 2020 Severity: 3-Major
When you try to discover a BIG-IP device that is version 15 and later, discovery might fail because BIG-IQ can't find an HTTP monitor path and an error is reported: "Error while transforming Pool, message 'Full path /Common/http2 has no matches.' was returned"
Discovery fails and BIG-IQ cannot manage pools or pool monitors that use a HTTP2 monitor.
-- Discovering a BIG-IP device version 15 or higher -- The BIG-IP system a pool or pool member with an http2 monitor associated with it
Remove the HTTP2 monitor from the pool and/or pool member and then try to discover the device again.
None