Bug ID 911729: Redundant learning suggestion to set a Maximum Length when parameter is already at that value

Last Modified: Feb 07, 2024

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1, 16.1.2.2, 16.1.3, 16.1.3.1, 16.1.3.2, 16.1.3.3, 16.1.3.4, 16.1.3.5, 16.1.4, 16.1.4.1, 16.1.4.2

Fixed In:
17.0.0, 16.0.1.2, 15.1.4, 14.1.4.2

Opened: May 26, 2020

Severity: 4-Minor

Symptoms

Policy Builder is issuing a learning suggestion to set a specific maximum length for a parameter when that parameter already has that exact maximum length already configured.

Impact

Redundant learning suggestion is issued.

Conditions

-- Response learning is turned on -- Response parameter length is less than, but close to, the currently configured maximum length limit.

Workaround

You can either: -- Ignore the learning suggestion (Click the Ignore button). -- Turn off Learn from response.

Fix Information

Learning suggestion is no longer issued with already configured maximum parameter length value.