Bug ID 912001: TMM cores on secondary blades of the Chassis system.

Last Modified: Sep 16, 2020

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Known Affected Versions:
13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 16.0.0, 16.0.0.1

Opened: May 27, 2020
Severity: 3-Major

Symptoms

When using DNS Cache on chassis systems with a forward zone pointing at a self IP for communication with local BIND, the following assert triggers: tmm_panic (... "../net/loop.c:572: %sIDX set on listener%s") at ../lib/stdio.c:1307

Impact

TMMs on secondary blades core dump. Traffic disrupted while tmm restarts.

Conditions

-- Chassis system is used. -- Secondary TMMs core dump. -- Primary works as expected.

Workaround

1) Create another virtual server that uses local Bind server. 2) Set the forward zones to point to that virtual server instead of the self IP as name servers.

Fix Information

None