Bug ID 921537: BIG-IQ does not support BIG-IP tunnel objects binding with local-traffic

Last Modified: May 29, 2024

Affected Product(s):
BIG-IQ ADC(all modules)

Known Affected Versions:
7.1.0, 7.1.0.1, 7.1.0.2, 7.1.0.3, 7.1.6, 7.1.6.1, 7.1.7, 7.1.7.1, 7.1.7.2, 7.1.8, 7.1.8.1, 7.1.8.2, 7.1.8.3, 7.1.8.4, 7.1.8.5, 7.1.9, 7.1.9.7, 7.1.9.8, 7.1.9.9

Opened: Jun 27, 2020

Severity: 3-Major

Symptoms

Config sync fails and tunnel objects are configured incorrectly across devices in a device group.

Impact

An incorrect tunnel object might be synced from one device to another device

Conditions

All of the following: 1) BIG-IP is using a tunnel object 2) The tunnel is assigned to traffic-group-local-only 3) BIG-IP is configured with Device Services Clustering with config sync enabled.

Workaround

A potential workaround is to have all tunnels on cluster reside on one BIG-IP device and import it last.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips