Bug ID 927621: Rolling upgrade blocked during Data Collection Device cluster upgrade

Last Modified: Jul 31, 2020

Bug Tracker

Affected Product:  See more info
BIG-IQ Device(all modules)

Known Affected Versions:
7.0.0, 7.0.0.1, 7.1.0

Opened: Jul 15, 2020
Severity: 3-Major

Symptoms

An error occurs during a rolling upgrade of Data Collection Device (DCD) cluster" "Detected multi-zone environment with insufficient number of DCDs in a single zone"

Impact

You are unable to perform a rolling upgrade

Conditions

-- 3 or more DCDs across all zones -- 2 or more DCDs in a single zone -- None of the DCDs are in the same zone as the Configuration Management (CM) device

Workaround

Change the zone of the CM device from 'default' to one of the other zones. You can modify the option in the UI under System-> This Device -> General Properties -> Edit Impact of workaround: This will restart elasticsearch and potentially initiate a rediscovery of all shards if a new master is elected.

Fix Information

None