Bug ID 942441: A data collection device (not the quorum one) is removed from active after autofailover happened

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IQ Platform(all modules)

Known Affected Versions:
7.1.0, 7.1.0.1, 7.1.0.2, 7.1.0.3, 7.1.6, 7.1.6.1, 7.1.7, 7.1.7.1, 7.1.7.2, 7.1.8, 7.1.8.1, 7.1.8.2, 7.1.8.3, 7.1.8.4, 7.1.8.5, 7.1.9, 7.1.9.7, 7.1.9.8, 7.1.9.9

Opened: Sep 03, 2020

Severity: 3-Major

Symptoms

After failover, the active device still has a monitor running on it. The data collection device goes offline and actively fences itself from the world. All data collection devices are removed.

Impact

All data collection devices are removed and they need to be manually added.

Conditions

This can occur when auto failover is enabled. The Active device has a data collection device (other than quorum) and it fails.

Workaround

None

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips