Bug ID 950837: Command 'show system blade-power' does not show current blade power state

Last Modified: Apr 28, 2025

Affected Product(s):
F5OS Velos(all modules)

Known Affected Versions:
F5OS-C 1.1.0, F5OS-C 1.1.1, F5OS-C 1.1.2, F5OS-C 1.1.3, F5OS-C 1.1.4

Opened: Oct 03, 2020

Severity: 3-Major

Symptoms

The CLI command 'show system blade-power' displays the power requested and allocated to a blade. It does not show the power currently being drawn by the blade.

Impact

The 'show system blade-power' command output does not change, so it is not a suitable method to determine the power status of blades in the system. There is no impact to the running system itself.

Conditions

Blade is powered off via AOM commands.

Workaround

Use AOM to check the blade power state if it is not possible to check blade indications visually. 1. Enter AOM. 2. Capture blade console. 3. Select Display Blade Information.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips