Bug ID 982189: Partition status displayed by system controller may not be accurate

Last Modified: Oct 19, 2025

Affected Product(s):
F5OS Velos(all modules)

Known Affected Versions:
F5OS-C 1.1.0, F5OS-C 1.1.1

Fixed In:
F5OS-C 1.1.2

Opened: Jan 13, 2021

Severity: 3-Major

Symptoms

The system controller may display a partition status of "running" rather than "running-active" or "running-standby".

Impact

Incomplete and possibly misleading status information is reported to the user.

Conditions

If the system controller component responsible for reporting the partition state restarts, or misses a state-transition message, the state will not be updated until the next state-transition.

Workaround

None

Fix Information

The state-reporting mechanism has been updated to account for missed messages or restarts, so that displayed status will be accurate.