Bug ID 990605: Tunnels created on BIG-IQ are not added to the default route domain of the other devices in the Device Service Cluster

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IQ ADC(all modules)

Opened: Feb 04, 2021

Severity: 4-Minor

Symptoms

When BIG-IQ creates a tunnel on a managed device that belongs to a Device Service Cluster (DSC), it also adds the tunnel to that device's default route domain. But when BIG-IQ replicates the tunnel to the other devices within a DSC, it does not add the tunnel to the route domain for those devices.

Impact

If no further steps are taken, the next deployment to the cluster will fail.

Conditions

Use BIG-IQ to add a tunnel to a BIG-IP device that is a member of a DSC.

Workaround

Manually add the tunnel to the route domain of the other devices in the DSC.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips