Bug ID 999125: After changing management IP addresses, devices can be stuck indefinitely in improper Active/Active or Standby/Standby states.

Last Modified: Feb 07, 2024

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.0.1.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.5, 14.1.0.6, 14.1.2, 14.1.2.1, 14.1.2.2, 14.1.2.3, 14.1.2.4, 14.1.2.5, 14.1.2.6, 14.1.2.7, 14.1.2.8, 14.1.3, 14.1.3.1, 14.1.4, 14.1.4.1, 14.1.4.2, 14.1.4.3, 14.1.4.4, 14.1.4.5, 15.0.0, 15.0.1, 15.0.1.1, 15.0.1.2, 15.0.1.3, 15.0.1.4, 15.1.0, 15.1.0.1, 15.1.0.2, 15.1.0.3, 15.1.0.4, 15.1.0.5, 15.1.1, 15.1.2, 15.1.2.1, 15.1.3, 15.1.3.1, 15.1.4, 15.1.4.1, 15.1.5, 16.0.0, 16.0.0.1, 16.0.1, 16.0.1.1, 16.0.1.2, 16.1.0, 16.1.1, 16.1.2, 16.1.2.1

Fixed In:
17.0.0, 16.1.2.2, 15.1.5.1, 14.1.4.6, 13.1.5

Opened: Mar 03, 2021

Severity: 3-Major

Symptoms

After a device (or multiple devices) in a sync-failover device-group undergoes a management IP change, multiple devices in the group can be stuck indefinitely in improper Active/Active or Standby/Standby failover states.

Impact

-- The affected units are unable to pass traffic, as they are either both Standby or Active (resulting in either no service availability or IP address conflicts in the network).

Conditions

-- One or more devices belonging to a sync-failover device-group undergo a management IP change.

Workaround

If you are planning to change management IP addresses on your devices, consider doing so during a maintenance window, in order to account for the eventuality this issue might occur. Then, if this issue does occur, you can restore correct system functionality by restarting the sod daemon on all units that had their management IP address changed. To do so, run the following command: tmsh restart sys service sod Note: This is a one-time workaround, and the issue may re-occur if the devices undergo further management IP address changes in the future.

Fix Information

Redundant devices remain in the correct failover state following a management IP address change.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips